Remote Mode Enable:

0 (Disabled)

Comm Port Address:

50

Comm Baud Rate:

9600

Geo Elev Position:

0

Azim Slow Speed:

253

Elev Slow Speed:

253

Angle Display Enable:

0 (Disabled)

Azim Scale Factor:

1

Azim

Offset:

0

Elev Scale Factor:

1

Elev

Offset:

0

Hemisphere:

1

(Northern

Hemisphere)

Rotating Feed Present?:

0 (No)

Pol Angle Display:

0 (Disabled)

Pol Display 0 Deg Count:

500

Pol Display 90 Deg Count:

750

Pol Motor Jog Duration: 1000 milliseconds (1 second)

Az/El Drive Options:

0 (CONFIG mode prompts disabled)

Azim Fast Slow Threshold:

80 position counts

Azim Coast Threshold:

4 counts

Azim Max Position Error:

1 count

Azim Auto Retry Attempts:

3

Azim Fast Deadband:

2000 milliseconds

Azim Slow Deadband:

800 milliseconds

Elev Fast Slow Threshold:

80 position counts

Elev Coast Threshold:

4 counts

Elev Max Position Error:

1 count

Elev Auto Retry Attempts:

3

Elev Fast Deadband:

2000 milliseconds

Elev Slow Deadband:

800 milliseconds