Table G-2 (Parameters Checked for Each Symbology)


Symbology

Ratio

ICG

Data
Character

Mod
Check

Tolerance

AIAG B-1

2.2-3.2

.5X-8X

STD CODE 39

N/A

((12R-8)/81)X

AIAG B-3
B-4 B-5


2.8-3.2


.5X-8X

$/+%
Not Allowed


N/A


((12R-8)/81)X

LOGMARS

2.2-3.0

.5X-8X

STD CODE 39

N/A

((12R-8)/81)X

CODE 3 OF 9

2.2-3.0

.5X-8X

STD CODE 39

N/A

((12R-8)/81)X

3 OF 9 W/43

2.2-3.0

.5X-8X

STD CODE 39
4 CHARS Min

MOD 43

((12R-8)/81)X

HIBC 3 OF 9

2.2-3.0

.5X-8X

STD CODE 39
Min 2 CHARS
1ST. = "+"

MOD 43

((12R-8)/81)X

INTERLVD 2 OF 5

2.2-3.0

N/A

N/A

N/A

((18R-1)/80)X

CASE CODE

2.3-2.9

N/A

3 Data Chars
Min.

MOD 10

((18R-1)/80)X

CODE 128

N/A

N/A

N/A

MOD 103

.35X

CASE
CODE 128

N/A

N/A

16 Data Char.
Format Check

Mod 10
Mod 102

.35X

UPC/EAN

N/A

N/A

N/A

MOD 10

See Note 1
(bottom of
pg.)

CODABAR
VARIANT

2.2-3.0

.5X-8X

STD
CODABAR

N/A

((5R-8)/20)X

CODE 93

N/A

N/A

STD CODE 93

C&K

.35X



Note 1:

• X = X dimension
Tolerance is expressed as a fraction of the X dimension

R = Ratio in the calculations

• UPC/EAN tolerances:

80 - 89% = .14X

90 - 115% = .30X

116 - 150% = .34X

151 - 200% = .38X

Advertising