Appendix j – RJS Inspector D4000 Auto Optic (FIRMWARE version A.05 and Earlier) User Manual

Page 61

Advertising
background image

Operator

s Guide

Appendix J

002-5564

RJS, Minneapolis, MN

54

Appendix J

Inspector 4000 Analysis Parameters

Reference Decode

This parameter grade can be “A” or “F.”

If the Reference Decode parameter is “F,” then the overall symbol grade is also “F”
(regardless of the grade of any other parameter).

If the Reference Decode parameter is “A,” then the overall symbol grade is determined by the
lowest of the other parameter grades.

When a symbol contains a global threshold failure (an element does not cross the global
threshold), other parameters cannot be analyzed.

In the case of a global threshold failure symbol contrast calculations are valid, however.

In the case of a global threshold failure, the Inspector 4000 will force the decodability
grade to 00% (an “F” grade).

Other affected grades will be calculated only for that portion of the symbol which was
scanned up to the point of the global threshold failure.


The Inspector 4000 also decodes each symbology with a more aggressive algorithm. This
enables many symbols to be scanned and decoded even though the reference decode grade is
an “F.”