19. ALARM 2 LOW SETTING 

 

 

Write Command: 28  

 

 

Read Command:  5c  
Interpret: 

Temperature reference to compare against secondary sensor for high 
alarm output.  Temperatures are in whole degree increments.  To turn 
the low alarm OFF set the alarm temperature to ‐21 (ffeb

16

). 

 
 

20. ALARM 2 HIGH SETTING 

 

 

Write Command: 29 

 

 

Read Command:  5d 
Interpret: 

Temperature reference to compare against secondary sensor for high 
alarm output.  Temperatures are in whole degree increments.  To turn 
the high alarm OFF set the alarm temperature to 200 (00c8

16

). 

 

21. ALARM LATCH FUNCTION 

 

 

Write Command: 2b 

 

 

Read Command:  5f  

 

 

Interpret: 

 

0 = NO LATCHES 

 

 

 

 

 

1 = ALARM 1 LATCH 

 

 

 

 

 

2 = ALARM 2 LATCH 

 

 

 

 

 

3 = ALARM 1&2 LATCH 

 

22. TEMPERATURE 2 DISPLAY 

 

 

Write Command: 2c 

 

 

Read Command:  60 

 

 

Interpret: 

 

0 = OFF 

 

 

 

 

 

1 = AUTOMATIC 

 

 

 

 

 

2 = ON 

 

23. ALARM 1 DEADBAND 

 

 

Write Command: 2d  

 

 

Read Command:  61  
Interpret: 

The span in temperature that the control sensor must move before 
the ALARM 1 output is toggled off. 

 

For writing, multiply desired deadband by 10

10

 then convert to 

hexadecimal. For reading, convert to decimal then divide by 10

10

 

 

 

 

 

1 degree would be 10

10

  

 

 

 

 

 

20 degrees would be 200

10

  

 

24. ALARM 2 DEADBAND 

 

 

Write Command: 2e 

 

 

Read Command:  62 
Interpret: 

The span in temperature that the secondary sensor must move before 
the ALARM 2 output is toggled off. 

 

For writing, multiply desired deadband by 10

10

 then convert to 

hexadecimal. For reading, convert to decimal then divide by 10

10

 

 

 

 

 

1 degree would be 10 decimal 

 

 

 

 

 

20 degrees would be 200 decimal 

 