N o t e

Refer to Figure 4-2. Each adjustment notch changes the physical position of
the tray by 0.5 mm (0.02 in). Moving the lever counter-clockwise moves the
tray inward and increases distance A. Moving the lever clockwise moves
the tray outward and decreases distance A.

Tray 2/3 Position Adjustment

4

If distance A is greater than distance B by more than 0.5 mm (0.02 in),
move the adjustment lever clockwise one notch.

5

If distance A is less than distance B by more than 0.5 mm (0.02 in), move
the adjustment lever counter-clockwise one notch.

6

After adjusting:

Re-install the tray.

Re-run the Paper Path Test.

Recheck the measurements.

Re-adjust as necessary.

Figure 4-2

4-8 Maintenance and Adjustments