12-Station Controllers

VacTrac™ Conveying Systems

STAGE DELAY: 3.000s

PRESS ENTER TO SAVE

SET LCD BLINK DELAY?

NO/YES

Pump stage time is a delay that prevents both pumps from
engaging at the same time. Although rare in a two-pump
system, both pumps can sometimes start at the same time. This
condition causes an excess of current on the electrical system
from such a surge.
The pump stage time delay defaults to 3.0 seconds and should
not be altered
unless you are instructed to do so by the AEC
Service Dept.

Using the keypad:

„

Enter the new time and press the

ENTER

key to save the new

setting.