12-Station Controllers

Page 69

SELECT PUMP 1 OR 2

USE KEYPAD TO ENTER

HV VENT DLY: 10.000s

SETTING FOR PUMP n

HI VAC LOAD COUNT?

NO/YES

At the above screen prompt:

„

Select the pump for altering vacuum vent delay.

The following screen displays.

Using the keypad:

„

Enter the new time and press the

ENTER

key to save the new

setting.

Setting the Hi Vacuum Load Count

At the above message prompt:

„

Press the

YES

key to enter the Hi Vacuum Load Count menu.

Hi vacuum load count sets the maximum number of loads on a
station in a high vacuum condition. If a station repeatedly
experiences a high vacuum condition for the selected number
of loads without being cleared or attended to, it goes off line to
prevent damage to the conveying system. This parameter
defaults to 7 loads and should not be altered unless you are
instructed to do so by the AEC Service Department.