Remote fault detection – H3C Technologies H3C S7500E Series Switches User Manual

Page 24

Advertising
background image

3-5

Ethernet OAM link events

Description

Errored frame period event

An errored frame period event occurs if the number of frame

errors in specific number of received frames exceeds the

predefined threshold.

Errored frame seconds event

When the number of error frame seconds detected on a port

over a detection interval reaches the error threshold, an

errored frame seconds event occurs.

z

The system transforms the period of detecting errored frame period events into the maximum

number of 64-byte frames that a port can send in the specific period, that is, the system takes the

maximum number of frames sent as the period. The maximum number of frames sent is

calculated using this formula: the maximum number of frames = interface bandwidth (bps) ×

errored frame period event detection period (in ms)/(64 × 8 × 1000)

z

If errored frames appear in a certain second, this second is called an errored frame second.

Remote fault detection

Information OAMPDUs are exchanged periodically among Ethernet OAM entities across established

OAM connections. In a network where traffic is interrupted due to device failures or unavailability, the

flag field defined in information OAMPDUs allows an Ethernet OAM entity to send error information to

its peer. In this way, you can keep track of link status in time through the log information and

troubleshoot in time.

Table 3-5

lists the critical link events and the transmission frequencies of the

corresponding OAMPDUs.

Table 3-5 Critical link error events

Ethernet OAM link events

Description

Link Fault

Peer link signal is lost.

Dying Gasp

An unexpected fault, such as power failure, occurred.

Critical event

An undetermined critical event happened.

Advertising