Configuring RRPP Timers

Perform this configuration on the master node of an RRPP domain.

Follow these steps to configure RRPP timers:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter RRPP domain view

rrpp domain domain-id

Configure the Hello timer and

Fail timer for the RRPP domain

timer hello-timer hello-value

fail-timer fail-value

Required

By default, the Hello timer value

is 1 second and the Fail timer

value is 3 seconds.

z

The Fail timer value must be equal to or greater than three times the Hello timer value.

z

To avoid temporary loops when the primary ring fails in a dual-homed-ring network, ensure

that the difference between the Fail timer value on the master node of the subring and that

on the master node of the primary ring is greater than twice the Hello timer value of the

master node of the subring.

Configuring RRPP Fast Detection

The S7500E series Ethernet switches support RRPP fast detection only after SD or EB cards

are mounted in them.

Enabling Fast Detection

Perform this configuration on the master node, edge node, and assistant-edge node in the

RRPP domain to be configured.

Follow these steps to enable fast detection:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter RRPP domain view

rrpp domain domain-id