5-13

z

Configure CC to monitor the connectivity among all the MEPs in MD_A and MD_B. Configure to

use LB to locate link faults or use LT to identify the paths between source and destination MEPs

or locate faults after the whole network status is obtained.

Figure 5-6 Network diagram for CFD configuration

Configuration procedure

1) Configure a VLAN and assign ports to it

On each device shown in

Figure 5-6

, create VLAN 100 and assign ports GigabitEthernet2/0/1 through

GigabitEthernet2/0/4 to VLAN 100.

2) Enable

CFD

# Enable CFD on Device A.

<DeviceA> system-view

[DeviceA] cfd enable

Enable CFD on Device B through Device E using the same method.

3) Configure

service

instances

# Create MD_A (level 5) on Device A, create MA_A, which serves VLAN 100, in MD_A, and create

service instance 1 for MD_A and MA_A.

[DeviceA] cfd md MD_A level 5

[DeviceA] cfd ma MA_A md MD_A vlan 100

[DeviceA] cfd service-instance 1 md MD_A ma MA_A

Configure Device E as you configure Device A.

# Create MD_A (level 5) on Device B, create MA_A, which serves VLAN 100, in MD_A, and then

create service instance 1 for MD_A and MA_A; in addition, create MD_B (level 3), create MA_B, which

serves VLAN 100, in MD_B, and then create service instance 2 for MD_B and MA_B.

[DeviceB] cfd md MD_A level 5

[DeviceB] cfd ma MA_A md MD_A vlan 100

[DeviceB] cfd service-instance 1 md MD_A ma MA_A

[DeviceB] cfd md MD_B level 3

[DeviceB] cfd ma MA_B md MD_B vlan 100

[DeviceB] cfd service-instance 2 md MD_B ma MA_B

Configure Device D as you configure Device B.