88

The fixed-area space for a queue cannot be used by other queues. Therefore, it is also called the

minimum guaranteed buffer for the queue.
To set the fixed-area ratio for a queue:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Set the fixed-area ratio for a
queue.

buffer egress [ slot slot-number ] cell
queue queue-id guaranteed ratio

ratio-value

The default setting is 12.5% for
each queue.
The sum of ratios configured for
queues cannot be greater than or

equal to 100%, and queues 5, 6,
and 7 must have available

fixed-area space.

Applying data buffer configuration

Perform this task to apply the data buffer configuration.
You cannot directly modify the applied configuration. To modify the configuration, you must cancel the

application, re-configure data buffers, and re-apply the configuration.
To apply data buffer configuration:

Step Command

1.

Enter system view.

system-view

2.

Apply data buffer configuration.

buffer apply

Displaying and maintaining data buffers

Execute display commands in any view.

Task Command

Display data buffer configuration.

display buffer [ slot slot-number ] [ queue [ queue-id ] ]

Display data buffer usage.

display buffer usage [ slot slot-number ]

Advertising