Installing a lightning protector for a network port

The lightning protector for a network port is only applicable to a copper Ethernet port.
If part of the network cable of a copper Ethernet port must be routed outdoors, connect a lightning

protector to the cable before you plug the cable into the port.
The following lightning protector for network ports is available for the firewall:

Type Port

description

Maximum discharge current
(8/20μs waveform)

Output voltage

1000M port lightning
protector

Single port

3 kA

Core-core < 15 V

Core-ground < 350 V

Required tools

Flat-blade screwdriver

Phillips screwdriver

Diagonal pliers

Multimeter

Installation procedure

IMPORTANT:

Read the instructions for the lightning protector carefully before you install it.

To install a lightning protector:

1.

Use a double-faced adhesive tape to stick the lightning protector onto the firewall chassis, and

make sure it is as close to the grounding screw of the firewall as possible.

2.

Measure the distance between the protector and the grounding screw of the firewall, cut the
ground wire of the protector as appropriate, and securely tighten the ground wire to the

grounding screw of the firewall.

3.

Use the multimeter to measure whether the ground wire of the protector contacts well with the
grounding screw of chassis.

4.

Insert the outdoor network cable into the protector's IN end, and the cable connected to the
firewall into the OUT end, and check the indicators on the lightning protector to verify that the

connection is correct.

5.

Use nylon ties to bundle the cables neatly.