Verifying and diagnosing transceiver modules, Verifying transceiver modules, Diagnosing transceiver modules – H3C Technologies H3C SecPath F1000-E User Manual

Page 64: Troubleshooting system exceptions, Configuring the exception handling methods

Advertising
background image

56

Verifying and diagnosing transceiver modules

The commonly used transceiver module is as follows:

Transceiver type Application scenarios

Whether can be an

optical transceiver

module

Whether can be an

electrical transceiver

module

Small Form-factor
Pluggable (SFP)

interface module

Generally used for
100M/1000M Ethernet

interfaces

Yes No

Verifying transceiver modules

To verify transceiver modules, use the display transceiver interface command to display the key

parameters of the transceiver modules, including transceiver module type, connector type, central

wavelength of the laser sent, transfer distance, and vendor name.
To display the transceiver module information:

Task Command

Remarks

Display key parameters of the transceiver
module in a specified interface.

display transceiver interface
[ interface-type interface-number ]

Available for all
transceiver modules

Diagnosing transceiver modules

The firewall provides the alarm function for transceiver modules for diagnosis.
To display the alarm information about transceiver modules:

Task Command

Remarks

Display the current alarm information for the
transceiver module in a specified interface.

display transceiver alarm interface

[ interface-type interface-number ]

Available for all
transceiver modules

For more information about the commands for transceiver modules, see H3C SecPath

F1000-E/F1000-S-EI Firewall Configuration Guides.

Troubleshooting system exceptions

Configuring the exception handling methods

You can use one of the following methods to handle system exceptions:

reboot—The firewall reboots to recover from the error condition.

maintain—The firewall stays in the error condition and does not take any measure to recover
itself, so you can collect complete data, including error messages, for diagnosis.

To configure the exception handling method:

Advertising