Replacement procedures, Precautions, Replacing a mini interface module – H3C Technologies H3C SecPath U200-A U200-M U200-S User Manual

Page 49: Replacing a mim interface module

Advertising
background image

40

Replacement procedures

Precautions

Always wear an ESD-preventive wrist strap or ESD-preventive gloves when servicing the UTM

device.

No interface modules for the UTM device are hot-swappable. Power off the UTM device before
replacing hardware.

When removing FRUs (such as Mini or MIM interface modules, and the CF card):

{

Ensure good alignment with the slot and use uniform force to avoid damage to the FRUs.

{

Completely loosen each captive screw before removing Mini or MIM interface modules to

keep their panels in good condition.

{

Hold a PCB by its edges. Do not touch any electronic components.

{

Put the removed FRUs on an antistatic workbench with the PCB side facing upward or place
them in antistatic bags.

Replacing a Mini interface module

1.

Loosen the two captive screws with a Phillips screwdriver.

2.

Holding the front part of the Mini interface module, gently pull it out along the slide rails.

3.

Install a new Mini interface module.
For the installation procedures, see "

Installing a Mini interface module

."

If no new Mini interface module is to be installed to the slot, install a filler panel to prevent dust
from entering the chassis.

Figure 41 Pulling out a Mini interface module

Replacing a MIM interface module

1.

Loosen the captive screws with a Phillips screwdriver.