Appendix B LEDs

UTM device panel LEDs

NOTE:

The LED descriptions of the U200-A, U200-M, and U200-S are similar. This chapter takes the U200-A
as an example.

Figure 45 U200-A LEDs

Table 27 LED description

LED Status

Description

ACT (yellow)

Off

No data is being transmitted or received.

Flashing

Data is being transmitted or received.

LINK (green)

Off

No link is present.

On

A link is present.

(green)

Off

No CF card is present or the CF card is not
recognizable.

On

A CF card is in position and has passed the power-on
self-test (POST).

Flashing

The system is accessing the CF card. Do not remove
the CF card in this state.

(green)

Off

The device has no power input or is faulty.

On

The system is faulty.

Slow flashing (1 Hz)

The device is operating properly.

Fast flashing (8 Hz)

The application software is being loaded, or the
device is not working.

(green)

Off

No interface module is present or the interface
module is faulty.

On

The interface module is operating properly.