Troubleshooting cooling system failures, Symptom, Solution – H3C Technologies H3C SecPath U200-A U200-M U200-S User Manual

Page 62

Advertising
background image

53

Troubleshooting cooling system failures

Symptom

The temperature inside the UTM device exceeds 45°C (113°F).

Solution

Verify that the fans are running properly.

Verify that the working environment of the UTM device is well ventilated.

If the temperature inside the UTM device exceeds 50°C (122°F), the following information appears
on the configuration terminal:

%Feb 27 11:34:39:949 2012 H3C DRVMSG/3/Temp2High:Temperature Point 0/0 Too High.

%Feb 27 11:34:42:557 2012 H3C DEV/4/BOARD TEMP TOOHIGH:

Board temperature is too high on Chassis 0 Slot 0, type is RPU.

Use the display environment command to examine whether the temperature inside the UTM
device is rising. If the temperature inside the UTM device exceeds 90°C (194°F), power off the

UTM device immediately and contact your local sales agent.

Troubleshooting interface module, cable, and

connection failures

Symptom

After a Mini/MIM interface module is installed and the UTM device is powered on, the LEDs on the
Mini/MIM interface module panel indicate that the interface module is not operating normally.

Solution

1.

Verify that the correct Mini/MIM interface module cable is used.

2.

Verify that the Mini/MIM interface module cable is correctly connected.

Use the display interface command to examine whether the interfaces of the interface module have

been correctly configured and are operating properly.