Grass Valley 2000NET v4.0.0 User Manual

Page 10

Advertising
background image

10

2000NET Instruction Manual

Installation

In a 1 RU frame, the 2000NET module installs in slot number 5 as shown in

Figure 4

.

Figure 4. 2000T1DNG Frame Front Module Locations

Note

The 2000NET module can be plugged in and removed from a 2000 Series
Kameleon frame with power on. When power is applied to the module, LED
indicators reflect the initialization process (see

Power Up on page 18

).

To install the 2000NET module in the 3 RU or 1 RU frame:

1.

Insert the module, connector end first (see

Figure 5

), with the

component side of the module facing up. Slide the module in until it
stops.

2.

Press on the connector tab to seat the module in place. There will be a
positive click when the module is fully seated.

Figure 5. 2000NET Module/Frame Orientation

(2)

(3)

(4)

(5)

(6)

(1)

8039-21

2000NET Network Interface Slot (5)

Power Supply Slot (7)

Front Media Slots (1-4)

2000GEN Reference Distribution Slot (6)

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

8046-07

Component side up