2000NET Instruction Manual

85

2000NET Software Update From FTP Server

Upgrading Software

With the FTPD running, use the 2000 GUI to initiate software updates. Use
the web-browser to:

Access the appropriate Software Update page for a given module,

Enter the required data into the HTML Form on that page, and

Submit the form.

The 2000 frame uses the data in the form to contact the FTPD on the
server, download the update file, and reprogram the targeted module.

Note

Prior to attempting update of software, refer to the target module’s manual
and confirm that the Remote/Local Only jumper is in the Remote position.

Note

To monitor the progress of the download, you may use the serial port con-
nection with a computer running a terminal emulation application.

a.

Open a web browser on a PC that is connected over the network to
the 2000 frame.

b.

Enter the URL of the frame where the module to be updated resides.
The frame’s main status page will appear.

c.

Click on the module’s link and then click on

Software Update

.

The module’s Software Update page will appear (

Figure 60

). This

form is the same for all 2000 modules that support network soft-
ware update.

Figure 60. Network Module Software Update Web Page

Use
this
link