Grass Valley 2000NET v4.0.0 User Manual

Page 63

Advertising
background image

2000NET Instruction Manual

63

Service

For Frame Bus Failure-Fixed events:

Check that the FRAME BUS switch (Switch 6) on the S1 DIP switch
block of the 2000NET module is Enabled, and

Check that the

FRAME BUS STATUS REPORTING

parameter on the

frame’s

CONFIGURATION

page is Enabled.

For Front Cover Removed -Installed events, check that the

COVER

STATUS REPORTING

parameter on the frame’s

CONFIGURATION

page is

Enabled.

For Frame Bus Failure-Fixed events:

Check that the FRAME BUS switch (Switch 6) on the S1 DIP switch
block of the 2000NET module is Enabled, and

Check that the

FRAME BUS STATUS REPORTING

parameter on the

frame’s

CONFIGURATION

page is Enabled.

For Cooling Fan Failure-Fixed events:

Check that the FAN switch (Switch 4) on the S1 DIP switch block of
the 2000NET module is Enabled, and

Check that the

FAN STATUS REPORTING

parameter on the frame’s

CON-

FIGURATION

page is Enabled.

For Module Health Failure-Fixed events,

Check that the MODULE switch (Switch 5) on the S1 DIP switch
block of the 2000NET module is Enabled, and

Check that the

MODULE HEALTH REPORTING

parameter on the frame’s

CONFIGURATION

page is Enabled.

Check that the SNMP Manager is properly configured to receive the
Event Messages.

Check that the SNMP Manager has been assigned the same commu-
nity name as in the frame’s configuration.

6.

Check the network connectivity between the SNMP Manager and the
frame as described in the steps on

page 58

.