2000NET Instruction Manual

Status Monitoring and Reporting

Rebooting the Module

If you need to reboot the 2000NET module, either remove and replace the
module in the slot or use the GUI to access the 2000NET Configuration or
Network pages. Both pages have a

reboot

button (see

2000NET Configuration

Web Page on page 46

or

2000NET Network Web Page on page 50

).

Status Monitoring and Reporting

This section provides a complete summary of frame status monitoring and
reporting in a Kameleon 2000 Series system with an 2000NET module
installed in the frame. It summarizes what status items are reported and
how to enable/disable reporting of each item. There are a number of ways
to monitor status of frame power supplies, fans, modules in the frame, and
other status items depending on the method of monitoring being used
including Frame Alarm (2000T3 frame only) and SNMP reporting.

Frame Status Reporting

2000 Frame status will report the following items:

Power supply health,

Status of fans in the frame front cover,

Temperature,

Module health, and

Frame bus status.

Module health status will report the following items:

Internal module state (and state of submodule or options enabled)
including configuration errors (warning), internal faults, and normal
operation (Pass).

Signal input states including valid/present (pass), not present or
invalid (warning), not monitored, and not available (no signal inputs).

Reference input states including locked/valid (pass), not locked/
invalid (warning), and not monitored.

Signal output states with reporting functionality (reference output).

The Module Health bus provides a means for older (legacy) or less capable
modules (such as DAs with no microprocessor) that cannot communicate
over the Frame serial bus to report alarm conditions to the Frame Monitor
or 2000NET module. The reporting is done using a voltage level sent by the
module. When a problem exists on the module, it will pulse or provide a

Advertising