Grass Valley 2000NET v4.0.0 User Manual

Page 61

Advertising
background image

2000NET Instruction Manual

61

Service

c.

Check The 2000NET module’s status page if the frame remote
control is disabled.

If so, flip Switch 3 on the S2 DIP switch block (FRAME CNTRL) to
the enabled setting.

3.

If only a specific parameter is read-only, the module may be in a mode
assigning read-only operation to that parameter. Refer to the module’s
instruction manual.

4.

If only the 2000NET module is read-only, the 2000NET module may be
in remote lockout mode.

a.

Check the 2000NET module’s status page to see if the

NET CARD

REMOTE CONTROL

status is disabled.

b.

If so, flip Switch 2 on the S2 DIP switch block (NM CNTRL) to the
enabled setting (see

Table 3 on page 22

)

.

Event Messages From the Frame Are Not Being Displayed by NetCentral or
Another SNMP Manager Application

1.

Check that the frame is powered on and configured with an 2000NET
module on the Network.

2.

Check that the 2000NET module in the frame is loaded with software
version 2.2.0 or later.

Earlier versions of software do not support SNMP.

3.

Check that the SNMP Agent has been installed and configured on the
2000NET module.

View the 2000NET module

CONFIGURATION

page and note the event con-

figuration parameters, the

NET CARD EVENT REPORTS

form and

REPORT

DESTINATIONS

table.

If these are not visible, install the SNMP Agent per the instructions in
the manual.