Functional Description

Functional Description

The 2000NET is designed to allow remote control and monitoring of
modules in a 2000 Series Kameleon frame. It communicates to remote
devices through an Ethernet connection. It communicates with modules in
the frame via the frame bus. It also performs the error monitoring of the
power supplies, modules, temperature and fans. It does error reporting
through on board LEDs, the front panel LEDs, and, on the 2000T3 frame
only, the frame alarm relay (via a DB-9 connector on the back of the frame).

Refer to the block diagram in

Figure 47

while reading the following func-

tional description.

Figure 47. 2000NET Block Diagram

SDRAM

16 MByte

FLASH

RAM

8 MByte

EEPROM

Flash

Boot

Module

Connector

Diagnostic

Display

Port

Input

Port

CPU

Bus

CPU

Multiplexer

Temperature

Sensors

I2C

SPI

Motherboard Connector

GP I/O

DIP switch

LEDs

Network

Interface

GPI

Optoisolators

A/D

RS232/RS422

Frame Bus

NET COM

Fan

Rotation

Sensor

In

Out

Sel

Out

Sel

Ser. A

Ser. B

Ref.

Power In

+5 V

+3.3 V

DC to DC

Converter

Regulators

PA

PB

PC

PD