2. Panel Operation

2 – 55

Operating Instructions – Rev. 1 / 7.2002

2.8.1.1

DSK Operating Mode 1 (default)

Pressing and holding down 2nd Func enables the use of the second function of
the DSK Cut and Auto buttons to perform the Couple function or to select the input
mode for the appropriate transition duration (also for FTB Auto). The 2nd Func
lamp is on during this operation mode.

Press Cut x if you wish to execute a transition as hard cut.

Holding down 2nd Func and pressing one Cut x button switches the appropriate
Couple mode of the DSK x on or off. Releasing the 2nd Func button disables the
second function mode and the lamp is off. The indicators 1 ... 8 then show which
keyers are coupled.

Press Auto to execute a transition of the type selected in the Transition panel using
the preset transition duration. If the Auto button is pressed again, the transition is
aborted. For external DSKs only MIX is possible.

Holding down 2nd Func and pressing Auto x button selects the input mode for
transition duration input of the appropriate DSK x or FTB. The numeric keypad is
delegated to numerical entry, the numeric buttons will light up and prompt for transi-
tion duration input. The actual transition duration value is displayed in the appropri-
tate mnemonic field (not for FTB). Enter the desired transition duration (input dis-
played in mnemonic field and numeric keypad display) via numeric buttons, use
Clear/FREE for input deletion if necessary. Confirm entry by pressing Enter/NEXT
or by pressing 2nd Func. The 2nd Func lamp will be switched off.

The coupled DSKs are indicated by the Coupl button and the indicators 1 ... 8.