A-2

Mechanical

Probes

Coaxial: 1.3 ft (0.4 m) to 19.7 ft (6 m).
Rigid Twin Lead: 1.3 ft (0.4 m) to 9.8 ft (3 m).
Flexible Twin Lead: 3.3 ft (1 m) to 77.1 ft (23.5 m).
Rigid Single Lead: 1.3 ft (0.4 m) to 9.8 ft (3 m).
Flexible Single Lead: 3.3 ft (1 m) to 77.1 ft (23.5 m).
For further information see “Probe Selection Guide” on page 2-6.

Tensile strength

Flexible Single Lead probe: 2698 lb (12 kN).
Flexible Twin Lead probe: 2023 lb (9 kN).

Collapse load

Flexible Single Lead probe: 3597 lb (16 kN).

Sideway capacity

Coaxial probe: 73.7 ft lbf, 3.7 lb at 19.7 ft (100 Nm, 1.67 kg at 6 m).
Rigid Twin Lead: 2.2 ft lbf, 0.22 lb at 9.8 ft (3 Nm, 0.1 kg at 3 m).
Rigid Single Lead: 4.4 ft lbf, 0.44 lb at 9.8 ft (6 Nm, 0.2 kg at 3 m).

Material exposed to tank atmosphere

• 316/316L SST (EN 1.4404), PTFE, PFA

(1)

and O-ring materials (model code 1)

• Hastelloy

®

C276 (UNS N10276), PTFE, PFA

(1)

and O-ring materials (model code 2)

• Monel

®

400 (UNS N04400), Teflon (PTFE, PFA) and O-ring materials (model code 3)

• PTFE

(2)

(model code 7)

• PTFE

(2)

, 316L SST (EN 1.4404) and O-ring materials (model code 8)

• 316L SST (EN 1.4404), Ceramics (Al2O3), Graphite, (HTHP probe, model code H)
• 316L SST (EN 1.4404), Ceramics (Al2O3), Graphite, PFA (HP probe, model code P)
(See “Ordering Information” on page A-12).

Dimensions

See “Dimensional drawings” on page A-7.

Probe angle

0 to 90 degrees from vertical axis.

Housing / Enclosure

Polyurethane-covered Aluminium.

Flanges, Threads

See “Ordering Information” on page A-12.

Height above flange

See “Dimensional drawings” on page A-7.

Environment

Ambient temperature

-40 °F to +185 °F ( -40 °C to +85 °C), depends on approval (see App. B).
For the LCD display the temperature range is -4 °F to +185 °F (-20 °C to +85 °C).
See temperature diagrams on page A-6.

Storage temperature

-40 °F to + 176 °F ( -40 °C to +80 °C).

Process temperature

(3)

Standard: -40 °F to +302 °F ( -40 °C to +150 °C).
HTHP: -76 °F to +752 °F ( -60 °C to +400 °C).
HP: -76 °F to +392 °F ( -60 °C to +200 °C).
See temperature and pressure diagrams on page A-4.

Process pressure

(3)

Standard

(4)

: Full vacuum to 580 psig ( -1 to 40 Bar).

HTHP: Full vacuum to 5000 psig (-1 to 345 Bar).
HP: Full vacuum to 5000 psig (-1 to 345 Bar).
See temperature and pressure diagrams on page A-4.

Humidity

0 - 100 % relative humidity

Ingress protection

NEMA 4X, IP 66.

Telecommunication (FCC and R&TTE)

FCC part 15 (1998) subpart B and R&TTE (EU directive 97/23/EC). Considered to be
an unintentional radiator under the Part 15 rules.

Factory sealed

Yes.

Vibration resistance

IEC 721-3-4 Class 4M4.

Electromagnetic compatibility

Emission and Immunity: meets EN 61326-1 (1997) and amendment A1, class A
equipment intended for use in industrial locations if installed in metallic vessels or
still-pipes.
When rigid/flexible single and twin lead probes are installed in non-metallic or open
vessels, influence of strong electromagnetic fields might affect measurements.

Built-in Lightning Protection

Meets EN 61000-4-4 Severity Level 4 and EN 61000-4-5 Severity Level 4.

Pressure Equipment Directive (PED)

Complies with 97/23/EC article 3.3.

Ordinary Location FM 3810,

Compliance.

Boiler Approval CSA B51-97

Compliance.