Rosemount 3300 series, Reference manual – Emerson Guided Wave Radar Level and Interface Transmitters 3300 User Manual

Page 109

Advertising
background image

Reference Manual

00809-0100-4811, Rev CA
February 2006

A-5

Rosemount 3300 Series

The HP and HTHP versions have a ceramic tank seal, and graphite gaskets -
no O-rings are used.

The difference between the HP and HTHP versions is spacer material; PFA
for HP, and ceramics for HTHP. Ceramic spacers allow for usage in
applications with higher temperature.

The following table gives the temperature ranges for tank seal with different
O-ring material (applicable for the Standard Tank Connection):

Table A-1. Temperature range
for different tank seal material.

Flange connection rating

Flange strength calculations are made with the following conditions:

Calculations show that the following rating applies:

ANSI

According to ANSI B16.5 Table 2-2.3.

Standard: max. 302 °F/580 psig (150 °C/40 Bar).

HP/HTHP: Class 2500.

EN

According to EN 1092-1 Table 18, material group 13E0.

Standard: maximum 302 °F/580 psig (150 °C/40 Bar).

HP/HTHP: PN 320.

Tank Seal with different
O-ring material

Min. Temperature
°F (°C) in air

Max. Temperature
°F (°C) in air

Viton

5 (-15)

302 (150)

Ethylene Propylene (EPDM)

-40 (-40)

266 (130)

Kalrez 6375

14 (-10)

302 (150)

Buna-N

-31 (-35)

230 (110)

Bolting material

Gasket

Flange material

Hub material

Standard/HTHP

HP/HTHP

ANSI

Stainless steel SA193
B8M C1.2

Soft (1a) with min.
thickness 1.6 mm.

Spiral wound gasket with
nonmetallic filler (1b)

Stainless steel A182
Gr. F316L and
EN 10222-5-1.4404.

Stainless steel A479M
316L or
EN 10272-1.4404.

EN

EN 1515-1/-2 group
13E0, A4-70.

Soft (EN 1514-1) with
min. thickness 1.6 mm.

Spiral wound gasket with
nonmetallic filler
(EN 1514-2)

Advertising