Rosemount 3300 series, Reference manual – Emerson Guided Wave Radar Level and Interface Transmitters 3300 User Manual

Page 119

Advertising
background image

Reference Manual

00809-0100-4811, Rev CA
February 2006

A-15

Rosemount 3300 Series

Model Code 3302, Level and Interface in Liquids

Model

Product Description

3302

Guided Wave Radar Level and Interface Transmitter

Code

Signal Output

H

4-20 mA with HART

®

communication

Code

Housing Material

A

Polyurethane-covered Aluminum

Code

Conduit / Cable Threads

1

½ - 14 NPT

2

M20 x 1.5 adapter

3

PG 13.5 adapter

Code

Operating Temperature and Pressure

S

- 15 psig (-1bar) to 580 psig (40 bar) @ 302 °F (150 °C)

(1)

(1) Process seal rating. Final rating depends on flange and O-ring selection. See “Process Temperature and Pressure Rating” on page A-4.

H

High Temp / High Pressure

(2)

: 2940 psi @ 750 °F and 5000 psi @ 100 °F (203 bar @ 400 °C and 345 bar @ 38 °C) according

to ANSI Class 2500 (Probe Type 3A, 3B and 4A)

(2) Requires option None for sealing (no O-ring). Only for SST (Material of Construction model code 1).

P

High Pressure

(2)

. Max 500 °F (200 °C): 3500 psi @ 500 °F and 5000 psi @ 100 °F (243 bar @ 200 °C and 345 bar @ 38 °C)

according to ANSI Class 2500 (Probe Type 3A, 3B and 4A)

Code

Material of Construction

(3)

: Process Connection / Probe

(3) For other materials, consult factory.

1

316 / 316 L SST (EN 1.4404)

2

Hastelloy

®

C-276 (UNS N10276). Available for probe type 3B and 4A.

3

Monel

®

400 (UNS N04400). Available for probe type 3B and 4A

7

PTFE covered probe and flange. Available for probe type 4A, Flanged version

8

PTFE covered probe. Available for probe type 4A

Code

Sealing, O-ring Material (Consult factory for other o-ring materials)

N

None

(4)

(4) Requires High Temperature High Pressure (code H) or High Pressure (code P) probe.

V

Viton

®

fluoroelastomer

E

Ethylene Propylene

K

Kalrez

®

6375 perfluoroelastomer

B

Buna-N

Code

Probe Type

Process Connection

Probe Lengths

1A

Rigid Twin Lead

Flange or 1.5 in. Thread

Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)

2A

Flexible Twin Lead with weight

Flange or 1.5 in. Thread

Min: 3 ft 4 in. (1 m). Max: 77 ft 1 in. (23.5 m)

3B

Coaxial for interface measurements

Flange, 1 or 1.5 in. Thread

Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)

4A

Rigid Single Lead

Flange, 1 or 1.5 in. Thread

Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)

Code

Probe Length Units

E

English (feet, inch)

M

Metric (meters, centimeters)

Code

Total Probe Length

(5)

(feet/m)

(5) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit. If

tank height is unknown, please round up to an even length when ordering. Probes can be cut to exact length in field. Maximum allowable length is
determined by process conditions.

xx

0 - 77 ft or 0-23 m

Code

Total Probe Length

(5)

(inch/cm)

xx

0 - 11 inch or 0-99 cm

Advertising