To load a setup

1. Click the Setup icon in the RCT workspace or choose the Setup option

from the File menu.

2. In the Setup window click the right mouse button and choose the Open

Setup option, or
from the File menu choose the Open Setup option.

3. Open the source folder and select the desired setup file.

4. Click the Open button.

Memory Map

The Memory Map window lets you view the current transmitter database
registers. It is also possible to save the current database for backup or service
purposes, and it is also possible to download a backup database to the
transmitter. To save configuration data in the Memory Map window:

1. Start the RCT program.

2. Choose the View>Memory option, or click the Memory Map icon in the

RCT workspace (Advanced section at the left side of the workspace
window).

3. Choose the All EE option from the drop-down list.

4. Click the Receive button. (It may take a few minutes to read the

database).

5. Click the right mouse button and choose the Save Memory As option.

6. Type the desired file name and click the OK button. Now the current

database is stored.

See the Online Help in RCT for further information on how to open a saved
database and how to download a database to the transmitter.