Setup - lcd, Setup - lcd -23, Rosemount 3300 series – Emerson Guided Wave Radar Level and Interface Transmitters 3300 User Manual

Page 75: Reference manual

Advertising
background image

Reference Manual

00809-0100-4811, Rev CA
February 2006

4-23

Rosemount 3300 Series

Setup - LCD

The LCD tab lets you specify which parameters to appear on the display
panel. The display has two rows, the upper row with five characters is for the
measured value and the lower row with six characters for the value name.
The display toggles between the different variables every 2 seconds.

Figure 4-18. Setup LCD tab

Choose one of the following options:

Table 4-3. LCD parameters

Parameter

Description

Level

Product level.

Distance

Distance from the upper reference point to the product surface.

Volume

Total product volume.

Internal Temperature

Temperature inside the transmitter housing.

Interface Distance

Distance between the upper reference point and the interface
between the upper and lower product.

Interface Level

Level of the lower product.

Interface Thickness

Thickness of the upper product.

Amplitude Peak 1

Signal amplitude of the reflected signal from the reference pulse.

Amplitude Peak 2

Signal amplitude of the reflected signal from the product surface.

Amplitude Peak 3

Signal amplitude of the reflected signal from the surface of the
bottom product (interface measurements).

Percent Range

Level value in percent of total measurement range.

Analog Output Current

4 -20 mA current.

RCT

-S

ETUP LCD