3) sgdv-de5a, 3wiring and connection, 2 system configuration diagram 3-19 – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 103

Advertising
background image

3.2 System Configuration Diagram

3-19

3

Wiring and Connection

(3) SGDV-DE5A

∗1. Use a 24-VDC power supply with double insulation or reinforced insulation. (The power

supply is not included)

∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

∗3. For connection to the command option module, refer to the user’s manual of the corre-

sponding option module.

∗4. The connected device and cable depend on the model of the linear scale.

R S T

*1

Noise filter

Molded-case

circuit breaker

(MCCB)

Magnetic

contactor

I/O signal cable

Power supply

Three-phase 400 VAC

Protects the power

supply line by shutting

the circuit OFF when

overcurrent is

detected.

Used to eliminate

external noise from

the power line.

Turns the servo

ON and OFF.

Install a surge

absorber.

Connection cable

for digital operator

Connection cable

for personal computer

Personal

computer

When not using the safety function,

use the SERVOPACK with the safety

function jumper connector

(JZSP-CVH05-E, provided as an

accessory) inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

SGDV-

DE5A

SERVOPACK

Digital

operator

Regenerative

resistor*

2

24VDC

power supply*

1

Option module*

3

External LED indicator,

external device, etc.

Linear servomotor

main circuit cable

Serial converter unit

*

4

Cable for connecting a

serial converter unit

*

4

Linear servomotor

with core

Linear scale

(Not included)

Cable for connecting a

hall sensor

Cable for connecting a

linear scale

*

4

Advertising