2) main circuit power input, 3) servopack main circuit wires – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 112

Advertising
background image

3 Wiring and Connection

3.3.3 When Using the SERVOPACK with a Single-phase 200 V Power Input

3-28

(2) Main Circuit Power Input

Connect a single-phase 200 V power supply of the following specifications to L1
and L2 terminals.

The specifications of the power supplies other than the

main circuit power supply are the same as for three-phase power supply

input

.

(3) SERVOPACK Main Circuit Wires

Terminal

Symbols

Terminal Name

Model

SGDV-A

Ratings

L1, L2

Main circuit power

input terminals

R70, R90, 1R6,

2R8, 5R5

Single-phase 200 V to 230 V,

+10% to

−15% (50/60Hz)

L3

*

None

∗ Do not use L3 terminal.

Terminal

Symbols

Terminal Names

形式

SGDV-A

R70

R90

1R6

2R8

5R5

L1, L2

Main circuit power input ter-

minals

HIV1.25

HIV2.0

L1C, L2C

Control power input terminals

HIV1.25

U, V, W

Linear servomotor connection

terminals

HIV1.25

HIV

2.0

B1/

, B2

External regenerative resistor

connection terminals

HIV1.25

Ground terminal

HIV2.0 or higher

Advertising