5 Trial Operation (Checking Linear Servomotor Operation)

5-12

5.4

Execution of Origin Setting (Fn020)

When using an absolute linear scale model ST78A manufactured by Mitutoyo
Corporation, execute the origin setting.

The origin setting can be executed by using either the digital operator or panel opera-
tor.

Using the Panel Operator

CAUTION

• Be sure to set the linear servomotor to the servo OFF state before executing

the origin setting function.

• Make sure that the parameter Fn010 (Write Prohibited Setting) is not set to

prohibit writing.

• After execution of the origin setting, the servo ready (/S-RDY) signal will

become inactive and the servo will be unable to draw power since the system

position data has been changed. Always turn the power supply OFF and then

ON again after execution of origin setting.

• After execution of the origin setting, the motor phase data in the SERVOPACK

will be lost. Execute the polarity detection (Fn080) and save the motor phase

data in the SERVOPACK.

• Origin setting using the utility function is required only for the initial setup.

If the position data is carelessly changed, the origin of the linear scale will be changed

and the machine may move in unexpected ways, resulting in damage to the product or

injury.

Step

Display after operation

Keys

Operation

1

Press the

Key to view the

main menu of Utility., and select
Fn020 using the

or

Key

.

2

Press the

Key.

The screen will change to the Fn020

(Origin Setting) main window.

3

or

Press the

or

Key to

select ORGSET5.

B B − F U N C T I O N −

F n 0 1 F : F B O p M o t I D
F n 0 2 0 : S − O r i g S e t
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t

O R G S E T 1

B B

S c a l e O r i g i n S e t

O R G S E T 5

B B

S c a l e O r i g i n S e t