3.3 Main Circuit Wiring

3-21

3

Wiring and Connection

∗1. Do not open short-circuit B1/

and B2 terminals. Doing so may damage the SERVO-

PACK.

∗2. The

1 and

2 is short-circuited with a jumper at the factory.

B1/

, B2

*1

External

regenerative

resistor

terminals

R70F, R90F, 2R1F, 2R8F,

R70A, R90A, 1R6A,

2R8A

If the regenerative capacity is insuf-

ficient, connect an external regener-

ative resistor (option) between B1/

and B2.

3R8A, 5R5A, 7R6A,

120A, 180A, 200A,

330A, 1R9D, 3R5D,

5R4D, 8R4D, 120D,

170D

If the regenerative capacity is insuf-

ficient, remove the wire or short bar

that shorts the connection between

B2 and B3, and connect an external

regenerative resistor (option)
between B1/

and B2.

550A, 260D

Connect a regenerative resistor unit
(option) between B1/

and B2.

1, 2

*2

DC reactor

connection

terminals for

power supply

harmonic

suppression

A

D

If a countermeasure against power

supply harmonic waves is needed,
connect a DC reactor between

1

and 2.

B1/

Main circuit

plus terminals

A

D

Use when DC power supply input is

used.

2 or

Main circuit

minus terminals

A

D

U, V, W

Linear

servomotor

connection

terminals

Use for connecting to the linear servomotor.

Ground

terminals

(

× 2)

Use for connecting the power supply ground terminal and linear

servomotor ground terminal.

(cont’d)

Terminal Symbols

Name

Model SGDV-

Description