2 servopack installation environment – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 25

Advertising
background image

2.1 Installation Environment and Applicable Standards

2-3

2

Installation

Impact Resistance: The linear servomotor will with stand the following

impact acceleration.

Installation site: An environment that satisfies the following conditions

• Indoors and free of corrosive or explosive gases

• Well-ventilated and free of dust and moisture

• Facilitates inspection and cleaning

• Free of high magnetic field

2.1.2 SERVOPACK Installation Environment

Surrounding air temperature: 0

°C to 55°C

Ambient humidity: 90% RH or less (with no condensation)

Altitude: 1,000 m or less

Vibration resistance: 4.9 m/s

2

Shock resistance: 19.6 m/s

2

Withstand voltage Voltage: 1,500 Vrms/m AC

Frequency: 50 or 60 Hz

Installation Precautions

• Mounting in a Control Panel

To prevent the temperature around the SERVOPACK from exceeding 55

°C, take into

account the size of the control panel, the layout of the SERVOPACK, and the cooling
method. For details, refer to 2.4 SERVOPACK Installation.

• Mounting Near a Heating Unit

To prevent the temperature around the SERVOPACK from exceeding 55

°C, suppress

radiant heat from the heating unit and temperature rise due to convection.

Servomotor model

Impact acceleration

SGLGW

SGLFW

SGLTW

196 m/s

2

× twice

SGLC

98 m/s

2

× twice