2.5 EMC Installation Conditions

2-41

2

Installation

Three-phase 200 V, SGDV-120A05A

Symbol

Cable Name

Specification

I/O signal cable

Shield cable

Cable for safety unit

Shield cable

Linear servomotor main circuit cable

Shield cable

Linear scale connection cables

Shield cable

Main circuit cable

Shield cable

1

3

4

5

2

Power supply:

Three-phase

200 VAC

Shield box

SERVOPACK

Clamp

Noise

filter

Clamp

Clamp

Clamp

Surge

absorber

Core

Core

Core

Core

Two turn

Two turn

Clamp

Linear

scale

Linear

servomotor

Host

controller

Safety unit

U, V, W

L1, L2, L3

L1C, L2C

CN2

CN1

PE

PE

CN8

One turn