5.5 Polarity Detection

5-23

5

T

rial Operation (Checking Linear Servomotor Operation)

5.5.4 Related Parameters

Pn481

Changes the sequence input signal allocation for

each signal

Setting Range

Setting Unit

Factory Setting

When enabled

10 to 20000

0.1 Hz

400

Immediately

Pn482

Polarity Detection Speed Loop lntegral Time

Constant

Setting Range

Setting Unit

Factory Setting

When enabled

15 to 51200

0.01 ms

3000

Immediately

Pn485

Polarity Detection Reference Speed

Setting Range

Setting Unit

Factory Setting

When enabled

0 to 100

1 mm/s

20

Immediately

Pn486

Polarity Detection Reference Accel/Decel Time

Setting Range

Setting Unit

Factory Setting

When enabled

0 to 100

1 ms

25

Immediately

Pn487

Polarity Detection Reference Constant Speed

Time

Setting Range

Setting Unit

Factory Setting

When enabled

0 to 300

1 ms

0

Immediately

Pn488

Polarity Detection Reference Waiting Time

Setting Range

Setting Unit

Factory Setting

When enabled

50 to 500

1 ms

100

Immediately

Pn48E

Polarity Detection Range

Setting Range

Setting Unit

Factory Setting

When enabled

1 to 65535

1 mm

10

Immediately

Pn490

Polarity Detection Load Level

Setting Range

Setting Unit

Factory Setting

When enabled

0 to 20000

1%

100

Immediately

Pn495

Polarity Detection Confirmation Force Reference

Setting Range

Setting Unit

Factory Setting

When enabled

0 to 200

1%

100

Immediately

Pn498

Polarity Detection Allowable Error Range

Setting Range

Setting Unit

Factory Setting

When enabled

0 to 30

1 deg

10

Immediately

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force

Speed

Position

Force