3.4 Connecting Regenerative Resistors

3-41

3

Wiring and Connection

3.4.2 Setting the Regenerative Resistor Capacity

When an external regenerative resistor is connected, make sure to set the
regenerative resistor capacity using the parameter Pn600

.

Be sure to set this parameter when installing an external regenerative resistor

to the SERVOPACK

.

Set the regenerative resistor capacity within tolerance

value. The set value differs depending on the cooling method of external

regenerative resistor:

• For natural air cooling method: Set the value maximum 20% of the actually

installed regenerative resistor capacity (W).

• For forced air cooling method: Set the value maximum 50% of the actually

installed regenerative resistor capacity (W).

(Example)100 W external regenerative resistor with natural cooling method

100 W

× 20% = 20 W, therefore, Pn600 = 2 (units: 10 W)

Note: 1. When the set value is improper, the generative overload alarm (A.320) is detected.

2. The factory setting of “0” is the value when the SERVOPACK’s built-in regenerative

resistor is used.

WARNING

• If 0 is set to the parameter Pn600 while an external regenerative resistor is con-

nected, the generative overload alarm (A.320) may not be detected. If the gen-

erative overload alarm (A.320) is not detected correctly, the external

regenerative resistor may be damaged and an injury or fire may result. Be sure

to set the parameter Pn600 to the capacity of the connected external regenera-

tive resistor.

Pn600

Regenerative Resistor Capacity

Setting Range

Unit

Factory

Setting

When Enabled

Classification

0 to SERVOPACK

capacity

10 W

0

Immediately

Setup

Speed

Position

Force

• When the external regenerative resistors for power are used at the

rated load ratio, the resistor temperature increases to between 200
°C and 300°C. The resistors must be used at or below the rated
values. Check with the manufacturer for the resistor’s load charac-
teristics.

• For safety, use the external resistors with thermoswitches.