2 Installation

2.1.1 Linear Servomotor Installation Environment

2-2

2.1

Installation Environment and Applicable Standards

The installation environment and the applicable standards for linear servomotors and
SERVOPACKs are described in this section.

2.1.1 Linear Servomotor Installation Environment

Ambient temperature: 0

°C to 40°C

Ambient humidity: 20% to 80% RH or less (with no condensation)

Altitude: 1, 000 m or less

Vibration resistance: The linear servomotor will withstand the

following vibration acceleration in three
directions: vertical, side to side, and front to
back.

Servomotor Model

Vibration Acceleration at

Flange

SGLGW

SGLFW

SGLTW

three directions

49 m/s

2

SGLC

Moving

Coil

three directions

24.5 m/s

2

Magnetic

Way

axis direction

24.5 m/s

2

vertical, hori-

zontal

4.9 m/s

2

Vertical

Vertical

Side to side

axis

direction

horizontal

Fron to back

Impact applied to SGLGW,
SGLFW, and SGLTW models

Impact applied to SGLC model