Surface to meter bridge, Internal module connections, Psu to audio engine – Logitek Electronic Systems Artisan User Manual

Page 19: Logitek

Advertising
background image

Logitek

3
Physical Installation

Surface to Meter Bridge

The Meter Bridge has a short 4-wire cable with an RJ-11 connector on the end. This is plugged into

the port labeled COM12 on the underside of the frame. The cable length is suitable to mount the
Meter Bridge

behind the Artisan frame. If alternative wiring is required, this can be replaced with a

custom made cable using flat telephone cable and RJ-11 connectors.

”

TIP:

The above only applies if using a physical Meter Bridge.

Internal Module Connections

Inside the frame two 25-pair connectors are broken out to individual RJ-11 port connections. There
is generally no requirement to replace these cables, as the lengths are made to suit the position of

each module.

PSU to Audio Engine

The Artisan Power Supply Unit connects to the Logitek Audio Engine using a balanced serial link.
Standard CAT5 or better cabling is recommended.


Systems are supplied with the Audio Engine AE-C6 controller card, which connects using an RJ45 at

the Audio Engine and the Artisan.

The Artisan is supplied with a CAT5 patch lead, to connect the AE-C6 to the Artisan Power Supply
Unit. This lead is sufficient for testing purposes; however, the Audio Engine will normally be located
away from studios.


You can use a dedicated CAT5 cable or existing structured cabling. If using structured cabling

systems, care should be exercised to ensure the Audio Engine connections are not confused with
other network outlets and that the link is not unintentionally “un-patched”.

¬

See Appendix B for connector pinouts.

Logitek Artisan Reference Manual

17

Advertising