Appendix E
Additional Protocol Commands
The above busses are used to set a lock on Bus assignment buttons on the Artisan. If the bus is on,
the respective assignment button for that channel will not operate on the Surface.


These Busses could be set inside a Trigger to prevent an operator from changing assignments on

certain faders. This is useful when network/clean feed mixes must be made, and you do not wish
the console operator to override or accidentally change an assignment.

Monitor Devices

BUS16

Monitor Hotkey 1 (upper left)

BUS17

Monitor Hotkey 2 (upper right)

BUS18

Monitor Hotkey 3 (lower left)

BUS19

Monitor Hotkey 4 (lower right)


The above Busses are used to address the four hotkey buttons for the Studio 1, Studio 2, Control
Room

& Offline Source select buttons.

The standard Device numbers for Artisan monitoring is as follows.

DEVICE42

Studio 1 Monitor

DEVICE43

Studio 2 Monitor

DEVICE44

Control Room Monitor

DEVICE46

Offline Source

”

TIP: The

Monitor Hotkeys can be programmed to perform actions inside Triggers, or

assigned a source route via ASM commands in the Init Trigger. The latter is the
recommend mode of operation – the required commands are detailed on the
following pages.