Appendix E
Additional Protocol Commands

Surface Configuration – Clock Control & Position

Used to control the position and settings of the Artisan time-of-day clock. (v2.0 and later)

Seq

Byte

Description

Notes

1

<02>

Start byte

2

<09>

Bytes to follow

3

<AE>

Command = Set Effect

4

<d#>

Device Number

Device Number of Meter Bridge in hex (53 = Port 1)

5

<41>

Type = Surface Config

6

<0B>

Command = Set Clock

7

<dt>

Data Byte = Mode

<00> = Off

<01> = On

(default = 01)

8

<dt>

Data Byte = Type

<00> = Big

<01> = Small

(default = 00)

9

<dt>

Data Byte = X Pos

<00> to <FF> = Left edge of first digit, in pixels

(default = 21h / 33d)

10

<dt>

Data Byte = Y Pos

<00> to <FF> = Bottom edge of first digit, in pixels (default = 50h / 80d)

11

<dt>

Data Byte = LCD #

<01> to <06> = LCD screen number, from left to right

(default = 01)


The following example will put the Artisan clock in its default position on LCD screen #1:


02 09 AE 53 41 0B 01 00 21 50 01

”

TIP: The

Artisan clock should be addressed to CHAN73 LINE15, and then positioned

using the command above. If the clock data is sent to another line, the clock will
display as a standard text clock as per Numix and Remora surfaces.

Surface Configuration – Timer Control & Position

Used to control the position and settings of the Artisan timers. (v2.0 and later)

Seq

Byte

Description

Notes

1

<02>

Start byte

2

<09>

Bytes to follow

3

<AE>

Command = Set Effect

4

<d#>

Device Number

Device Number of Meter Bridge in hex (53 = Port 1)

5

<41>

Type = Surface Config

6

<cm>

Command = Timer No. <15> = Timer 1 Control <16> = Timer 2 Control

7

<dt>

Data Byte = Mode

<00> = Off

<01> = On

(default = 01)

8

<dt>

Data Byte = Type

<00> = Big

<01> = Small

(default = 00)

9

<dt>

Data Byte = X Pos

<00> to <FF> = Left edge of first digit, in pixels

(default = 21h / 33d)

10

<dt>

Data Byte = Y Pos

<00> to <FF> = Bottom edge of first digit, in pixels (default = 50h / 80d)

11

<dt>

Data Byte = LCD #

<01> to <06> = LCD screen number, from left to right

(default = 05)


The following example will enable Timer #1 in big mode in its default position on LCD screen #5.

02 09 AE 53 41 15 01 00 21 50 05