Epson Stylus TX100 User Manual

Page 32

Advertising
background image

Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300

Revision A

TROUBLESHOOTING

Error Indications and Fault Occurrence Causes

32

Confidential

• Power on
• Anywhere

When turning on the power, the PF Motor

does not operate at all

PF Motor

1. Check if the PF Motor Cable is connected to J6 on the

Main Board.

1. Connect the PF Motor Cable to J6 on the Main

Board.

2. Check if the PF Motor Cable is damaged.

2. Replace the PF Motor with a new one.

3. Check if the PF Motor operates.

3. Replace the PF Motor with a new one.

When turning on the power, the Carriage

Unit collides to the Change Lever located

to the front side of the printer.

PF Motor

1. Check if the PF Motor Connector Cable is connected to

J6 on the Main Board.

1. Connect the PF Motor Cable to J6 on the Main

Board.

2. Check if the PF Motor Connector Cable is damaged.

2. Replace the PF Motor with a new one.

3. Check if the PF Motor operates.

3. Replace the PF Motor with a new one.

ASF Unit

1. Check if the Compression Spring comes off from the

Change Lever.

1. Replace the Change Lever and the Compression

Spring with new ones.

Table 3-2. Check point for Fatal error according to each phenomenon

Occurrence timing

CR position

Detailed phenomenon

Defective

unit/part name

Check point

Remedy

J6

PF Motor Cable

Change Lever

Compression Spring

Advertising