Epson Stylus TX100 User Manual

Page 67

Advertising
background image

Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300

Revision A

DISASSEMBLY/ASSEMBLY

Removing the Circuit Boards

67

Confidential

4. Remove the screw that secures the Grounding Wire, and remove the

Grounding Wire from the Power Supply Unit.

Figure 4-24. Removing the Power Supply Unit

„ When installing the Grounding Wire, make sure that the

terminal of the Grounding Wire gets contact with the plate of
the Power Supply Unit as shown in

Fig.4-24

.

„ Route the Power Supply Unit Cable through the two ribs of

the Lower Housing. (See

Fig.4-23

.)

SCREW M3x8 P-TITE (5±0.5kgfcm)

Terminal

Grounding Wire

Power Supply Unit

„ When installing the Power Supply Unit, insert its protrusion to

the hole of the Lower Housing, and align the rib and dowel of
the Lower Housing with the positioning hole of the Power
Supply Unit.

Figure 4-25. Installing the Power Supply Unit

A D J U S T M E N T

R E Q U I R E D

Whenever the Power Supply Unit is removed/replaced, the
required adjustments must be carried out.

Chapter 5 “ ADJUSTMENT” (p.100)

Dowel

Positioning Hole

Protrusion

Rib

Advertising
This manual is related to the following products: