DISASSEMBLY/ASSEMBLY

Disassembling the Printer Mechanism

71

Confidential

4.5.2 CR Scale

† Parts/Components need to be removed in advance:

Scanner Stand/Cover Wire (

p 60

), Scanner Unit (

p 62

), Middle Housing (

p 63

)

Panel Unit (

p 64

)

† Removal procedure

1. Release the Carriage Lock and move the Carriage to the center. (See

"4.5.1

Printhead (p68)"

.)

2. Remove the right side of the CR scale from the hook.
3. Pull out the CR Scale through the slit of the CR Encoder Sensor.

Figure 4-35. Removing the CR Scale (1)

4. Detach the Extension Spring from the Main Frame.
5. Remove the CR Scale from the rib of the Main Frame.

Figure 4-36. Removing the CR Scale (2)

C A U T I O N

„ Do not touch the CR Scale with bare hands.
„ Do not damage the CR Scale.
„ Do not stretch the Extension Spring too much.

Hook

CR Scale

CR Scale

CR Encoder Sensor

Slit

„ When installing the CR scale, confirm that the arrows on both

the edges of the CR scale face upward.

„ Make sure to put the CR scale through the slit of the CR

Encoder Sensor. (See

Fig.4-35

.)

„ Make sure to confirm that the Extension Spring is not twisted,

then install the eye of the spring to the hole of the Main Frame.
(See

Fig.4-36

.)

A D J U S T M E N T

R E Q U I R E D

Whenever the CR Scale removed/replaced, the required
adjustments must be carried out.

Chapter 5 “ ADJUSTMENT” (p.100)

Main Frame

Extension Spring

CR Scale

Rib

Hole