DISASSEMBLY/ASSEMBLY

Removing the Circuit Boards

65

Confidential

„ Buttons

1. Remove the Button Power and the Button OP from the Panel Cover.
2. Remove the LED Lens from the Panel Cover.

Figure 4-19. Removing the Buttons

4.4.2 Main Board

† Parts/Components need to be removed in advance:

Scanner Stand/Cover Wire (

p 60

), Scanner Unit (

p 62

), Middle Housing (

p 63

)

Panel Unit (

p 64

), Hopper (

p 72

)

† Removal procedure

1. Remove all the cables and FFCs connected to the Main Board.

Figure 4-20. Removing the Main Board (1)

„ When installing the Panel Board, align the positioning hole of

the Panel Board with the dowels of the Panel Cover. (See

Fig.4-18

)

„ When installing the Panel Unit, align the positioning holes of the

Middle Housing with the dowels of the Panel Cover, then secure
them with four hooks. (See

Fig.4-16

,

Fig.4-19

.)

Button Power

Button OP

LED Lens

Panel Cover

Dowel

CN No

Cable

Cable Color

Connector

Color

Pins

J2

Panel FFC

---

Black

10

J3

Power Supply Unit cable

Gray

Brown

3

J4

Scanner FFC

---

Black

12

J5

Scanner Motor Cable

Black,Brown,

Orenge,Yellow

White

4

J6

PF Motor Cable

Red,

Black

White

2

J7

CR Motor Cable

Gray,

Black

Brown

2

J8

Head FFC

---

Black

21

J9

FFC

---

Black

17

Main Board

J3

J6

J7

J2

J4

J5

J8

J9