TROUBLESHOOTING

Error Indications and Fault Occurrence Causes

47

Confidential

Table 3-10. Check point for the abnormal noise

Occurrence

timing

CR position

Detailed phenomenon

Defective

unit/part name

Check point

Remedy

• Anytime
• Anywhere

The abnormal noise occurs at the first

power on timing and during each

operation although the printing

operation is performed.

Carriage Unit

1. Check if the grease on the Carriage Path is sufficient.

(TBD)

1. Wipe off the remaining grease on the Carriage

path and lubricate it on its frame.

(TBD)

ASF Unit

1. Check if the Change Lever moves smoothly.

1. Replace the ASF Unit with a new one.

The bottom of the Carriage Unit contacts
the surface of the EJ Frame Assy.

EJ Frame Assy

1. Check if the EJ Frame Assy is bent up.

1. Replace the EJ Frame Assy with a new one.

The Carriage Unit collides to the Upper

Paper Guide Unit during each operation. Upper Paper Guide

1. Check if the Upper Paper Guide is attached securely.

(check if it interferes with the Carriage Unit)

1. Reassemble the Upper Paper Guide to the

Main Frame.

Table 3-11. Check point for the defective scanned image quality

Print Quality

State

Detailed phenomenon

Defective

unit/part name

Check point

Remedy

• Scanned image is

not clear.

There are dusts or the like on the

Document Glass. (white dots appear on

the scanned image)

Upper Scanner

Housing

1. Check if there is foreign material on the Document

Glass.

1. Remove the foreign material from the

Document Glass.

(Refer to

Chapter 6 “MAINTENANCE”

(p.108)

.)

There are dusts or the like on the LED

inside the Rod Lens Array. (vertical

stripes appear on the scanned image)

CIS Unit

1. Check if there is foreign material on the LED.

1. Remove the foreign material from the CIS

Unit. (blow away the dusts)

2. Check if the Rod Lens Array is damaged.

2. Replace the CIS Unit with a new one.

The LED of Scanner CIS Unit does not

light up.

CIS Unit

1. Check if the LED lights up.

1. Replace the CIS Unit with a new one.