TROUBLESHOOTING

Error Indications and Fault Occurrence Causes

33

Confidential

• Power on
• Anywhere

The Carriage Unit collides with the Upper

Paper Guide Unit when power is turned

on.

Upper Paper Guide

1. Check if the Upper Paper Guide is correctly assembled.

1. Reassemble the Upper Paper Guide to the Main

Frame correctly.

When turning on the power, the Carriage
Unit collides to the right side of the Main
Frame.

CR Scale

1. Check if the CR Scale does not come off or it properly

passes through the slit of the CR Encoder Board.

1. Reassemble the CR Scale correctly.

* If the problem is not solved, replace the Main

Board with a new one.

2. Check if the CR Scale is damaged or contaminated.

2. Replace the CR Scale with a new one or clean it

completely.

Table 3-2. Check point for Fatal error according to each phenomenon

Occurrence timing

CR position

Detailed phenomenon

Defective

unit/part name

Check point

Remedy

Upper Paper Guide

Slit of the CR Encoder Board

CR Scale