Scheduling front panel lockout periods, Preliminar y, Special applications, cont’d – Extron Electronics MLC 104 Plus Series User Manual

Page 114

Advertising
background image

Special Applications, cont’d

MLC 104 Plus Series • Special Applications

5-10

PRELIMINAR

Y

(1, 2, 3, or 4) and %23 is the URL-encoding for the pound symbol

character (#). (This command is described in more detail on

page 4-34

.)

N

If for any reason you are not able to enter asterisks (*) or other special characters

as ASCII text here, try changing the special characters to their hex equivalent
(%2A for an asterisk, %23 for the pound sign ((#)) ) to enter them in this field.

d.

Click the green arrow adjacent to the Press area.

e.

For Toggle, click 1 to associate the IRCM-DV+’s DVD control with the

first button press.

f.

Click Internal SIS.

g.

Type in the SIS command to activate the IRCM-DV+’s VCR half:

X?

*2*24%23 or

X?

*2*24# where

X?

is the IRCM-DV+’s DIP switch setting

(1, 2, 3, or 4).

h.

Click the green arrow adjacent to the Press area.

13.

If desired, configure the button’s lights.

a.

In the Button Operations area, click the Light Control tab.

b.

Click on the desired button light setting, a combination of color and

action (nonblinking, slowly blinking, fast blinking).

c.

Click the green arrow adjacent to the Release area.

d.

For Toggle, click 1 (or 2) to associate that button lighting setting with

the first (or second) button release. In this example, the button will light

green (nonblinking) at the first button release.

e.

Repeat steps 13b through 13d to select a different button light setting for

the other (second) button release.

14.

To each toggle action, add a command to switch the input of the projector or

switcher.

15.

Complete the rest of the configuration as described in the MLC 104 Plus Series

Setup Guide

and in the Global Configurator help file: configure all control

ports for IR or RS-232 communication and select device drivers, configure the

rest of the buttons (including IRCM-DV+ buttons). Configure e-mail settings

and set scheduling as appropriate, then save the project and build and upload

the configuration to the MLC.

Scheduling Front Panel Lockout Periods

For additional security you can set up an automated schedule to either completely

prevent front panel changes or to restrict who can make front panel selections and

adjustments during certain hours and days. For full details, including instructions