Preliminar y, Special applications, cont’d – Extron Electronics MLC 104 Plus Series User Manual

Page 120

Advertising
background image

Special Applications, cont’d

MLC 104 Plus Series • Special Applications

5-16

PRELIMINAR

Y

c.

Select Conditions in the Monitored Conditions area.

d.

Select Digital Input 2 as the subject port and select Digital I/O Port is
Closed

as the option:


e.

Click Apply Condition.

f.

Select Actions in the Monitored Conditions area.

g.

Select the name of the projector or display in the Subject Port area

(NEC MT1050, in this example).

h.

Select the projector or display’s power-on command in the Available

Options area.


i.

Click Apply Condition.

j.

Click Done.

k.

Set up the second monitored condition by following steps 2a-2j but

typing in the second condition’s name (HSA in down position), selecting
Digital Input 3

as the subject port, and selecting the projector or display’s

power-off command in the Available Options area.

The two monitored conditions are

summarized in the Monitored Conditions area,

as shown at right.

3.

Save the configuration, then build and upload it to the MLC.