Special Applications, cont’d

MLC 104 Plus Series • Special Applications

5-18

PRELIMINAR

Y

In this example a 2-button switch is configured to have the MLC send e -mail alerts

to alerts to a security desk or to an administrative office when a button is pressed.

1.

In the Advanced Configuration tab

in the Global Configurator

software, configure the MLC’s

digital I/O ports (ports 2 and 3 in

this example) for digital input, as

shown at right.

2.

Set up a monitor for each port in the Monitor tab of Global Configurator.
a.

Click the Monitor tab (

), then

click Add Monitor (near the bottom of the GC window). The Monitor

Conditions Wizard window appears.

b.

Type in the name of the first monitored condition: Safety office alert.

c.

Select Conditions in the Monitored Conditions area.

d.

Select Digital I/O 1 as the

device or subject port and select
Digital I/O Port is Closed

as the

option, as shown at right.

e.

Click Apply Condition.

f.

Select Email in the Monitored

Conditions area.

g.

If you did not already create a notification e-mail, click Email Manager

(the Email

Manager

window opens),

type in the name,

subject, and main

text, click Add,

then click Done

to return to the

Monitored

Conditions

Wizard window.

h.

If the contact person for this alert is not listed in the Contacts section,

click Contact Manager (the Contacts Manager window opens), type in

the names, e-mail address, and company information, click Add, then

click OK to return to the Monitored Conditions Wizard window.