Preliminar y – Extron Electronics MLC 104 Plus Series User Manual

Page 33

Advertising
background image

2-17

MLC 104 Plus Series • Operation, Features, and Cabling

PRELIMINAR

Y

MLC104 DigOutput-03

MLC 104 Plus Series

+12 V

+12 V

2k

Ohms

LED

Digital

Output

GND

CTL

SW 1

Pin 1, 2,

or 3

The digital

output pin

drives an LED

using the

+12 VDC

output of the

controller as a

voltage source.
The LED lights

only when the

I/O pin is set

to “on”

(switch 1 is

closed).

N The I/O pin is capable of sinking a maximum of 250 mA from 12 VDC, max.

MLC104 DigOutput-04

Lamp

MLC 104 Plus Series

+12 V

+12 V

Digital

Output

+12 V Out

GND

CTL

SW 1

The digital

output pin

drives an

incandescent

lamp using the

+12 VDC

output of the

controller as

the voltage

source.
The lamp lights

only when the

I/O pin is set

to “on”

(switch 1 is

closed).

N The I/O pin is capable of sinking a maximum of 250 mA from 12 VDC, max.

d

MLS connector — To control an optional Extron switcher or other RS-232

controllable device, connect a cable between this 3.5 mm direct insertion

captive screw connector and the RS-232 port of the other device. By default

this port supports any Extron switcher without additional drivers. If it is used

to control other products, additional device drivers may be required.

N

The commands issued from this port are standard Extron SIS commands, and

they follow the typical Extron RS‑232 protocol:
• 9600 baud
• 8 data bits
• 1 stop bit
• no parity

If you connect an optional switcher (such as an Extron MLS Series or PVS

Series switcher) to the MLC, you must connect a ground wire between the

switcher and the MLC, as shown in the following diagrams.

Advertising